Modular classroom acoustics and TGD-021-5 compliance
Department of Education Technical Guidance Document TGD-021-5 sets maximum mid-frequency reverberation time at 0.6 s for primary classrooms and 0.4 s for SEN, autism and hearing-impaired teaching rooms, alongside airborne wall insulation and heavy-rain roof damping.
How factory-built steel school modules meet strict Irish speech-intelligibility, reverberation time, partition insulation and roof rain-noise limits.
Free, no obligation. One local supplier prices it, not five.
- RT ≤ 0.6 smainstream primary classroom cap
- RT ≤ 0.4 sSEN / autism & hearing room cap
- DnT,w ≥ 45–50dB partition isolation between rooms
- 30–35 dBAindoor mechanical noise ceiling

Four acoustic tests a modular classroom must pass in Ireland
Lightweight modular walls and flat roofs can easily sound hollow or drum loudly in Atlantic downpours unless acoustic engineering is built into the factory section from day one. Under TGD-021-5, independent acoustic testing before handover checks four separate performance figures:
Reverberation time (Tmf)
- Irish TGD-021-5 benchmark
- ≤ 0.6 s primary / ≤ 0.4 s SEN
- How modular builders achieve it
- Class A mineral-fibre or perforated acoustic ceiling tiles plus high-level acoustic wall panels in SEN bases.
Airborne partition insulation (DnT,w)
- Irish TGD-021-5 benchmark
- ≥ 45 dB standard / ≥ 50 dB SEN & SET
- How modular builders achieve it
- Double-leaf independent stud frames, acoustic mineral wool infill, twin layers of 15 mm dense soundboard and full perimeter acoustic seals.
Heavy rain noise on roofs
- Irish TGD-021-5 benchmark
- Limited to ≤ 25 dB above ambient floor
- How modular builders achieve it
- High-mass insulated composite or built-up warm roof with dense acoustic deck board and deep mineral wool above ceiling.
Indoor mechanical & impact sound
- Irish TGD-021-5 benchmark
- ≤ 30–35 dBA plant; L'nT,w ≤ 60 dB floors
- How modular builders achieve it
- Attenuated low-velocity MVHR ducts and composite cementitious upper floor decks on two-storey school blocks.
Price my classroom
Four quick taps and our Irish classroom budget appears before we ask for a phone number. One local supplier rings you, not five.
A SEN / autism special class suite, 150 to 220 m² (2 rooms / SEN suite), permanent turnkey build: €380,000 to €780,000 ex VAT.
How this budget guide is worked out
Permanent turnkey figures reflect going Irish school modular rates (€2,200 to €3,400/m² ex VAT for mainstream rooms and €2,500 to €3,700/m² ex VAT for SEN autism suites) built to 60-year structural design life, NZEB Part L A2/A3 BER, Part M access and TGD-021-5 acoustics on a level yard with reasonable crane access. Unit-and-crane rates exclude groundworks, pad foundations and service connections. Hire rates show weekly rental ex VAT with mobilisation, craneage and foundations noted separately. VAT is 13.5% on qualifying supply-and-install building contracts and 23% on modular hire. Complex ESB upgrades, storm attenuation tanks, road closures or statutory BCAR/FSC/DAC fees are priced after a site walk.
Why acoustic specification is non-negotiable in SEN and SET rooms
Children with autism, sensory processing differences or mild hearing loss struggle disproportionately when background ventilation hum or classroom echo blurs consonant sounds. Fixing reverberation after handover is cheap only if ceiling heights allow extra baffles, whereas fixing a noisy steel roof or flanking noise between twin SET rooms requires stripping walls and ceilings. Insist on written TGD-021-5 acoustic compliance and pre-completion sound testing in every permanent school tender.
Related school modular guides
SEN & autism special suite150–250 m² sensory, withdrawal, central activity and assisted-hygiene bases.
Mainstream 80 m² classroomTGD-022 floor layout, en-suite WC, wet area, NZEB heating and turnkey costs.
SET & resource room15–30 m² small-group teaching spaces, acoustic partition specs and yard siting.
Permanent 60-year vs prefabStructural steel frame, U-values, acoustic floors and 20-year lifecycle cost.
ASA scheme & modular frameworkHow Additional School Accommodation funding and modular frameworks operate.
NZEB, heat pumps & MVHRPart L A2/A3 BER, air-to-water or VRF heat pumps and classroom CO2 control.School modular questions answered
Does heavy Irish rain drum loudly on a permanent modular classroom roof?
Not when built to TGD-021-5. A warm built-up single-ply roof over dense structural decking and 150 to 200 mm mineral wool insulation damps downpours just as effectively as a slate roof.
What is the difference between 0.6 s and 0.4 s reverberation time?
Lowering reverberation time from 0.6 s to 0.4 s cuts room echo energy dramatically, creating the noticeably calm, hushed acoustic feel required in SEN autism bases and speech-and-language SET rooms.
When is acoustic testing carried out?
An accredited Irish acoustic consultant tests unoccupied furnished rooms after commissioning and before the BCAR Certificate of Compliance on Completion is lodged.
Every Irish modular classroom page and guide
Room types
TGD & compliance
Regional coverage

Check your classroom budget before any call
Select the room type, approximate m² and buy or hire route. When you want a written school proposal, your brief goes to a single modular school supplier in your county.